this is not for the un-initiated. ive been involved in one of the piping
modifcation of our air-sep unit. to even attempt to venture on this one must
have understanding of the ASTM G128. The hazards of O2 are also summarized
in NFPA 50, etc. this type of service require special cleaning of your
piping prior to commmsiioing. for a starter check out Swagelok Spec SC-11
regarding the cleaning requireemtn for O2 service.
sure like to discuss piping allowables for pumps, compressor and turbine and the problem we have encountered on our carbonate pump system and the design of a thermosyphon reboiler piping (if you've got an evaporator system) and the design of piping for the turbine wash system according to Tom Sawyers, etc but .i'm signing-off. i have already disturb a lot of people
we're also heavy user of API 510 and 653 but gotta go now. its been fun. Received on Thu May 31 08:18:00 2001
This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:12 EST