A 300 lb. cl., ASTM A-105 forged c/s (group 1.1) flange can handle up to a
max. of 650 psig at 325 degrees F. THis is from the B16.5 standard table 2.
> Anyone want to take a crack at this one? Instinctively, I'd guess
> that a 300# rated system would be OK but some of you with more
> steam experience than I might want to comment.
>
> Paul
>
>
> ----- Original Message -----
> From: Tom J
> Subject: PIPING SYSTEM PRESSURE CLASSIFICATION
>
>
> > Paul,
> >
> > I was referred to you by Bruce Jeffers (one of the people on the
> "Steam
> > List"). I am working on a 325 deg. F. MTW system design where I
> need to
> > maintain a minimum system static pressure set point of 275 psig
> to prevent
> > flashing to steam at the high point in the system. I have a MTW
> > circulating pump in the closed system. For the required flow
> rate, the
> > circulating pump must produce an additional 370 feet of head
> (about 160 psi
> > disregarding the decrease in density of the heated fluid).
> Adding the 160
> > psig to the static head requirement of 275 psi I get a total of
> 435 psi at
> > the discharge of the pump. This pressure will gradually
> decrease as you
> > travel further down the piping system (away from the pump
> discharge).
> >
> > What is the minimum system pressure-temperature classification
> for the
> > piping, fittings, and flanges for this system?
> >
> > I find a copy of standard B16.5 that appears to indicate that a
> 300 lb.
> > Primary Service Pressure Rated system could be used up to 680
> psi (non-s
> > hock).
> >
> > Please comment.
> >
> > Thank you,
> >
> > Tom
>
>
> _____________________
> Piping Design Central
> [ http://www.PipingDesign.com ]
> ________________________________________
> We hope you find this newsletter useful.
> If not, you can unsubscribe at:
> <a href="/group/PipingDesign/post?postID=6_oNS-Xbv2kp-dpM68gFLKQBiL0Jr5bP-md-Pq9YE9KI4Q4uH_kJIpFGaIRZj_rqcDgWxeujtLgCcQpw-dzU7H_5C1RH49LKeKEYYZtkiqw1">PipingDesign-unsubscribe@yahoogroups.com</a>
> Post message: <a href="/group/PipingDesign/post?postID=p-pmFXJZDNQeic3CullDQNxpmE6avJiQBI2DVfbLLBbwklQGXd6CuSQpI1vDxSzW8wbuukxcOfUwEra5zUB0IzK4wR78">PipingDesign@yahoogroups.com</a>
> Subscribe: <a href="/group/PipingDesign/post?postID=tDQlN4gGItLfLcF9R4-OFbS9VADobNliEQpAYyKlF14xw9MrBQwokIHeO7AzrBRwKX86l9ScAypBr_2sbnaK6EqGtOKSX1-uCvlFk40">PipingDesign-subscribe@yahoogroups.com</a>
>
> Your use of Yahoo! Groups is subject to <a href="http://docs.yahoo.com/info/terms/">http://docs.yahoo.com/info/terms/</a>
>
>
>
Received on Fri Jun 08 09:22:00 2001
This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:12 EST