RE: SRV exhaust pipe sizing

From: <SARE>
Date: Tue Jun 12 2001 - 02:59:00 EDT


You may want to try this.
The determination of the thrust load for the tail pipe of the relief valve can be calculated using the procedure of API-RP 520 (section 2.4.1 for open discharge system) or the Crosby Manual. May I caution you to account for the instantaneous force at the time the psv pops by considering the dynamic load factor. the API makes no mention of the dynamic load factor. You may look it up in B31.1

hope this helps.

  -----Original Message-----
From: M. Sundararajan [mailto:msundar@bangalore.tce.co.in] Sent: 08 June, 2001 11:19 AM
To: 'PipingDesign@yahoogroups.com' Subject: [PipingDesign] SRV exhaust pipe sizing

Hi everybody,

I would like to know the code reference and the procedure to calculate the Safety relief valve exhaust piping design for Natural gas service. Non-mandatory rules of Appendix-II of ASME B31.1 gives the method to calculate for steam services and not for gas services.

Can anybody please provide the above information for me.

Thank you

M.Sundararajan



Piping Design Central
[ http://www.PipingDesign.com ]

We hope you find this newsletter useful. If not, you can unsubscribe at:
<a href="/group/PipingDesign/post?postID=zlBLRP9V8_KvQadZt24RY7OkQf1kUiBLU9UKtLlK8x4c2vzVXOxbg514Ho4h3SonyoA03IqCMtmCF5LkBZTa-JyO78gXZTILd9yOENa5YZpJ">PipingDesign-unsubscribe@yahoogroups.com</a> Post message: <a href="/group/PipingDesign/post?postID=3bZWWWBU_MEobRTNFH3shON7bUzc5hAVywd8pT5U2TxZPz0Z49oFNISCWgnqY59fQJjMQ1gHj-azPhsw7eBCKiyUiA">PipingDesign@yahoogroups.com</a> Subscribe: <a href="/group/PipingDesign/post?postID=x5L7RECDpIF3ANbi5afj4iIesNAjOidf20cWd9DyRsZ_tbOXElqLWSPzFhjhE9us5xrWmYYqpRsyNbaHAFpSqT_rGsOr16JiLkckmQ">PipingDesign-subscribe@yahoogroups.com</a>

Your use of Yahoo! Groups is subject to <a href="http://docs.yahoo.com/info/terms/">http://docs.yahoo.com/info/terms/</a> Received on Tue Jun 12 02:59:00 2001

This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:12 EST