>1. Is it ok permissible to seal weld a threaded joint that was observed to
>be leaking during the hydro?
If you're talking about a shop hydro, no welding is permitted after the
hydro. Why are you seal welding it? If the joint isn't tight something's
wrong with it, so you might want to look into what the problem is first.
Christopher Wright P.E. |"They couldn't hit an elephant from <a href="/group/PipingDesign/post?postID=DXpsd0w4b_amiLk5MoZK63pIl1NUD7dUojy7dEvqJWb_bSxn66d-cyo5uBynfE7CI3NOMNhI5f0DH5g-zg">chrisw@skypoint.com</a> | this distance" (last words of Gen.
___________________________| John Sedgwick, Spotsylvania 1864)<a href="http://www.skypoint.com/~chrisw">http://www.skypoint.com/~chrisw</a> Received on Sun Jun 24 15:25:00 2001