>1. Is there a max temperature limit for the use of reinfocrcing pad (and
>start using a tee)?
Not generally--check the code rules for your construction
>2. Is there any rule-of-thumb to figure out the size of the reinforcing pad
>given just the nominal size of header?
You need to address the area replacement requirements in the Code
>3. What is the max permissible gap between the periphery of the reinf. Pad
>and to the pipe to ehich it is attached.?
This is a weld procedure issue. What are your fit-up requirements? I seem
to recollect that 1/16 as a rule of thumb for root gaps but it depends on
the weld design and the electrode size.
Christopher Wright P.E. |"They couldn't hit an elephant from <a href="/group/PipingDesign/post?postID=FQjbdpBe-WPfWyrEb4VSXcmAc4toKNoyka_gWLTUGCeppAI8Mwjfwg85GhgMMgpjV7rIGN_doJpbvFZMP80">chrisw@skypoint.com</a> | this distance" (last words of Gen.
___________________________| John Sedgwick, Spotsylvania 1864)<a href="http://www.skypoint.com/~chrisw">http://www.skypoint.com/~chrisw</a> Received on Sun Jun 24 15:25:00 2001