RE: New at PipingDesign.com: 08 August 2001 - Heat Exchangers

From: <SARE>
Date: Thu Aug 09 2001 - 01:53:00 EDT


one of the most practical heat exchanger book i have ever used is the one written by Stanley Yokel. i can remember the problem we're having where the first 3 rows of tubes have expereinced leaks (evaporators). Cause of tube failure is the impingement od the steam . The fix we have impelented came straight from Stanley book and it works. No leakers for the past5 years. Same thing with the flange leaks on our vaporizer (big) where we have extreme temp condition (high temp differential) Again the basis of our repair came from Stanley and again it works.

The Airetool has provided free seminars dealing with the heat exchanger retubing in the past - compelete with certificates.