RE: pipe wall thickness

From: <James>
Date: Thu Oct 04 2001 - 09:00:00 EDT


Hi Ralph

>he factor in the mill tolerance in the equation for the min. req'd
>thicknes..
>if u let hmtr = 1-mill tolerance and c = mechl allowance +CA
>then tm = (t+c)/hmtr or (t+c)/0.875 for 12.5%

My understanding of the spreadshhet was that tR = (min thickness + corrosion)/0.875

The 0.875 could be a factor for mill tolerance, but the mill tolerance should be subtracted from the nominal wall, not added to the min thickness as it is a manufacturer's tolerance based on the nominal wall.

The mill tolerance is used correctly in the column TA = T * 0.875, so the tR column seemed to be redundant.

Regards

Barbara