Satish
The problem is not the piping but rather the AST. The settlement of the tank
is more serious than the routing of the piping. Fix the settlement (using
API 653 Tank Inspection Code), then maybe u dont have to modify the
piping..Currenlty we're doing bottom plate replacement, shell repair and
correction of settlement in about 4 process tanks - the whole works such
NDE, geotechnical survey, CUI, CP upgrade, fitness-for-purpose assessment,
etc.
My recommendation is check first the mech'l entigrity (suitability for service) of the AST then focus on the piping.
> ----------
> From: Satish N[SMTP:n.satish@pg.siemens.co.in]
> Iam doing pipe routing around a water storage tank area, in which we
> have a settlement of tanks as 150mm,so in order to over come
> that settlement i may have to do some flexiable routing of pipe,so please
> provide some information about the flexiable connenctions which
> have to be used for this purpose.this is a cold water service lines.
>
> regards,
> Satish.N
>
>