Satish,
It would not be necessary for you to go for any flexible routing. The first support at the tank would be an adjustable support. This support shall be placed at a distance from the nozzle so that it will not have any reaction forces on the nozzle. OR
Support the pipe from the tank itself if possible, provided the second support is at a sufficient distance.
The option of using a flexible hose for 300 to 500mm also cannot be ruled out.
Let me know the final decision that you have made.
cheers