Re: Flow Elements - Recommendation

From: <V.R.H.P.>
Date: Sun Nov 25 2001 - 23:51:00 EST

Rakesh,
I suppose you are looking for the philosophy behind deciding the straight lenths before and after flow element.
It links to theory of Boundary Layer and Secondary Flows in fluid path. After any bend, there will be secondary flows induced near the pipe wall...it proportionately effects local velocity/pressure of the fluid. Considering the length of pipe required to reach to full velocity of liquid, standard straight lengths ahead of Flow Element are established. For after FE, also staright length is required to reach to full velocity after the Vena Contracta condition at FE.
Hope it clarifies upto some extent.

Macharla
--- saud <saud@bushnak.com> wrote:
> Dear Rakesh
>
> The standard recommended dimensions upstream and
> downstream of a flow
> measuring instrument sensor (paddle wheel type etc.)
> is 10 times the
> diameter of the pipe (D) for upstream and 5 D for
> down stream.
>
> With latest magnetic flow meters, this dimension is
> reduced to 5 D and 2 D
> respectively.
>
> Regards
>
> Saud
> ----- Original Message -----
> From: "RAKESH PATIL" <rpa@epc.ltindia.com>
> To: <PipingDesign@yahoogroups.com>
> Sent: Friday, November 23, 2001 6:15 PM
> Subject: [PipingDesign] Flow Elements
>
>
> > ** High Priority **
> >
> > Can anybody give me the basic criteria behind
> deciding the upstream and
> downstream dimensions between Flow Element and
> connecting Fitting /
> accessories in piping?
> >
> > regards,
> > rakesh
> >
> >
> >
> >
> ___________________________________________________
> > If you want only site update notifications, go
> here:
> > mailto:PipingDesignNews-subscribe@yahoogroups.com
> > _____________________
> > Piping Design Central
> > [ http://www.PipingDesign.com ]
> > ________________________________________
> > We hope you find this newsletter useful.
> > If not, you can unsubscribe at:
> > PipingDesign-unsubscribe@yahoogroups.com
> > Post message: PipingDesign@yahoogroups.com
> > Subscribe: PipingDesign-subscribe@yahoogroups.com
> >
> > Your use of Yahoo! Groups is subject to
> http://docs.yahoo.com/info/terms/
> >
> >
>
> Disclaimer :
> Our server is equipped with a Virus protection
> system and scans most recent viruses automatically
> prior to receiving / sending messages. We have taken
> maximum possible care by installing state-of-the-art
> protection programs to safeguard against viruses.
> However, since there can be no absolute protection,
> we are not responsible for any damage, loss of data
> and/or hardware damage caused by viruses to the
> recipients of mails sent or received through our
> server.
>
> Bushnak Water Group
> www.bushnak.com
>
>
>
>
>



Do You Yahoo!?
Yahoo! GeoCities - quick and easy web site hosting, just $8.95/month. http://geocities.yahoo.com/ps/info1 Received on Sun Nov 25 23:51:00 2001

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:23:55 EDT