Hi Shabaz Khan
depends on your code, welding procedure, testing requirements, equipment,
location (field or shop joint) and motivation of the welder.
If you can tell me the wall thickness, composition, etc etc
Assuming sch40 wall thickness, mild steel and no code requirements I would
allow 6 manhours for precut, prep, weld in a shop. 4 hours for weld alone,
given decent rotation gear.
For coded work add 50%. for TIG root allow another hour.
Cheers,
Steve McKenzie
>
> How long a 14", X-52, ERW pipe joint would normally take in welding?
> Regards,
> Shahbaz Khan
>
>
> _____________________________________________________
> Unsubscribe: PipingDesign-unsubscribe@yahoogroups.com
>
> Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
>
>
>
Received on Thu Mar 28 02:34:00 2002