RE: Piping Queries - II

From: <SARE>
Date: Mon May 06 2002 - 02:38:00 EDT

oh man, i wish i had this suggestion when we started the conc. sleeper remidiation program last year. for the really bad ones (and there are a couple of dozens of them) we just provided temp support, excavate, precast the sleeper, demolish the old one and install the new one , backfill, compact, fix the pipe and we're done.

we're going to consider your suggestion in the future repair and probably incorporate it in our standard design. many thanks.

-----Original Message-----
From: Gang Cvg [mailto:cvg_gang@yahoo.com] Sent: 06 May, 2002 8:31 AM
To: PipingDesign@yahoogroups.com
Subject: RE: [PipingDesign] Piping Queries - II

Dear Sare, Ralph H.,

In case you happen to design a grass root level pipe sleeper system, the feasibility of driving one pile ( at least ) per sleeper may solve the problem of "SINKING" sleepers. Received on Mon May 06 02:38:00 2002

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:23:56 EDT