Re:(PipingDesign) an question

From: <Ravichandran>
Date: Thu May 16 2002 - 10:17:00 EDT

Operating temperature is the one to be used for thermal expansion analysis and critical nozzle loads checking.Maximum operating temperature including the margin for instrument errors become the design temperature will be higher than the operating temperature. However conservatively it has become the general practice to analyze for the design temperature itself.

Regards,

K.V.RaviChandran
Senior Piping Engineer
Foster Wheeler Eastern Pte. Ltd.



Disclaimer

     ' The information contained in this email and the files transmitted with it are
confidential and intended only for the use of the individual or entity to whom they are addressed.If you have received this message in error, please immediately notify the sender and delete the mail. The views or opinions presented in this email are those of the author and do not necessarily represent those of the company. The recipient should check this email and any attachments for the presence of viruses. Foster Wheeler Eastern Pte Ltd accepts no liability for any damage caused by any virus transmitted by this email.' Received on Thu May 16 10:17:00 2002

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:23:57 EDT