Re: Anchor Forces & Moments

From: <SubrataP_Saha@ril.com>
Date: Mon Jun 24 2002 - 09:00:00 EDT

The design will depend on the type of anchors. 1.) Trunnion anchors (duck-foot design) - Piping Scope -Design is basically of the trunnion treated as the pipe member. There are standard formulas available for duckfoot design.

        Structural Scope - The connected structure / foundation. 2) Shoe - Anchor - Piping scope - Attachments welded to the pipe ie. shoe / axial stops etc. The individual members may be checked in design for elastic limit for the different loading conditions. The structural properties may be taken from the appropriate Steel Tables.If required structural dept may be consulted. But I feel some typical anchors may be modelled and analysed in STAAD and kept as reference. It is not a difficult job.

       Structural Scope - The connected Structure. This was the case for static loadings. For dynamic loading the stiffness and mass of the support should also be considered for accurate analysis of the piping system.

"Tushar, Zope " <zope_tushar@fwc.com> on 06/24/2002 08:38:00 PM

Please respond to PipingDesign@yahoogroups.com

To: <PipingDesign@yahoogroups.com>
cc:
Subject: [PipingDesign] Anchor Forces & Moments

Friends,

In one of our projects, Anchor forces & moments is the cause of arguments & discussions of the experts.

How do we check that the anchor forces & moments are with in the allowable limits? I mean the anchor itself does not fail.

Is there any formula to check the strength of the anchor? In this case how to
calculate the allowable value for (Fx, Fy, Fz & Mx, My, Mz).

Thanks & regards.

Tushar Zope
Piping Engineer
Foster Wheeler Eastern Pte. Ltd, Singapore Ph: 6890 0774 Fax: 6223 2989

Disclaimer
'The information contained in this email and the files transmitted with it are
confidential and intended only for the use of the individual or entity to whom
they are addressed. If you have received this message in error, please immediately notify the sender and delete the mail. The views or opinions presented in this email are those of the author and do not necessarily represent
those of the company. The recipient should check this email and any attachments
for the presence of viruses. Foster Wheeler Eastern Pte Ltd accepts no liability
for any damage caused by any virus transmitted by this email.'



Unsubscribe: PipingDesign-unsubscribe@yahoogroups.com

Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/ Received on Mon Jun 24 09:00:00 2002

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:23:57 EDT