RE: Anchor Forces & Moments

From: <Samuel>
Date: Mon Jun 24 2002 - 11:47:00 EDT

Following MSS (Manufacturers Standardization Society of the Valve and Fitting Industry, Inc.) Standards: MSS SP-58_1993, MSS SP-69_1996, and MSS SP-89_1998 may help you out of there.

Best Regards,

Samuel Liu

-----Original Message-----
From: Tushar, Zope [mailto:zope_tushar@fwc.com] Sent: Monday, June 24, 2002 8:08 AM
To: PipingDesign@yahoogroups.com
Subject: [PipingDesign] Anchor Forces & Moments

Friends,

In one of our projects, Anchor forces & moments is the cause of arguments & discussions of the experts.

How do we check that the anchor forces & moments are with in the allowable limits? I mean the anchor itself does not fail.

Is there any formula to check the strength of the anchor? In this case how to
calculate the allowable value for (Fx, Fy, Fz & Mx, My, Mz).

Thanks & regards.

Tushar Zope
Piping Engineer
Foster Wheeler Eastern Pte. Ltd, Singapore Ph: 6890 0774 Fax: 6223 2989

Disclaimer
'The information contained in this email and the files transmitted with it are
confidential and intended only for the use of the individual or entity to whom
they are addressed. If you have received this message in error, please immediately notify the sender and delete the mail. The views or opinions presented in this email are those of the author and do not necessarily represent
those of the company. The recipient should check this email and any attachments
for the presence of viruses. Foster Wheeler Eastern Pte Ltd accepts no liability
for any damage caused by any virus transmitted by this email.'



Unsubscribe: PipingDesign-unsubscribe@yahoogroups.com

Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/

[Non-text portions of this message have been removed] Received on Mon Jun 24 11:47:00 2002

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:23:57 EDT