Re: Fwd:Vibration from flashing valve

From: <andoks_lichon>
Date: Sat Jun 29 2002 - 06:00:00 EDT

sounds like the sizing of the control valve has failed to consider the effect of flashing. fixed the control valve and you fixed the vibration of the line.

> > Subject: Vibration from flashing valve
> > Author: KV Ravichandran
> > Date: 6/25/02 8:55 AM
> >
> > Hi,
> > Can any one give guidelines for quelling vibrations from flashing
control
> > valve.
> > This is my problem
> > There is in one 8" Zirconium line carrying acetic acid/ catalyst
from
> > reactor
> > to flash tank. At the flash tank side the line has one flashing
control
> > valve ,
> > gate valve and a conical expander section of about 4.6m long
where the pipe
> > dia
> > increases from 10" to 26" and connects to the flash tank
eccentrically.The
> > source of vibration is the flashing control valve (shear stream
ball
> > valve)which
> > throttles from 26 bars to 2 bars. The liquid flow velocity is
about 8.5m/s
> > at
> > the valve.Operating temperature of the line is 193 deg C.
> > During the original design two phase flow and vibration was
considered and
> > the
> > line is supported with TICO Vibration isolation pads and U bolt
clamps.
> >
> > Now the platform from the flash tank as well as the structure
supporting the
> > piping near the flashing valve is vibrating.
> >
> > To have an idea about the magnitude of the vibration following is
the latest
> > measurements at the flashing valve.
> > Fcy Velocity
> > Hz mm/sec
> > 4.405 1.418
> > 8.811 1.049
> > 13.22 .6426
> > 22.03 .6278
> > 48.46 1.876
> >
> > Thanks in advance
> >
> >
> > Regards,
> >
> > K.V.RaviChandran
> > Senior Piping Engineer
> > Foster Wheeler Eastern Pte. Ltd.
> >
> >
> >
> >
> >
> > _____________________________________________________
> > Unsubscribe: PipingDesign-unsubscribe@y...
> >
> > Your use of Yahoo! Groups is subject to
http://docs.yahoo.com/info/terms/
> >
> >
>
>
> =====
> Design Detail and Development
> We specialise in pipe network and waterhammer analysis, pipe stress
analysis, buried pipelines and the design of thermoplastic pipe systems.
> Local tel 0402 35 2313 fax 02 8850 2313
> Overseas tel 61 402 35 2313 fax 61 2 8850 2313
>
> __________________________________________________
> Do You Yahoo!?
> Yahoo! - Official partner of 2002 FIFA World Cup
> http://fifaworldcup.yahoo.com
Received on Sat Jun 29 06:00:00 2002

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:23:57 EDT