Hi Mahavir
your dilemma occurs sometimes with pumps. One way it is overcome is to have the equipment supplier provide flanged ends on his equipment and also to supply mating flanges (and gasket if necessary) to your pipe material spec.
Cheers
Steve McKenzie
-----Original Message-----
From: Prasad Mahavir/Piping [mailto:jainmp@eil.co.in]
Sent: Thursday, July 04, 2002 3:30 PM
To: PipingDesign@yahoogroups.com
Subject: RE: [PipingDesign] Flanged connections with dissimilar
Materials
Hi folks,
I guess that type of flange facing would also play a role. For example if the flange is with RTJ ends and gasket being used is solid octagonal or oval, then I would not like to exercise option 2. Any Comments?
Mahavir
-----Original Message-----
From: NIRMAL MURARKA [mailto:Nirmal-Murarka@enc.ltindia.com]
Sent: Wednesday, July 03, 2002 5:55 PM
To: PipingDesign@yahoogroups.com
Subject: [PipingDesign] Flanged connections with dissimilar Materials
For a spec break with change in material near a flanged joint (may be equipment flange and piping flange) what should be the correct approach:
May be temperature and type of materials will play a key role. When can we go with option # 2 safely ?
Yahoo! Groups Sponsor
Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
[Non-text portions of this message have been removed]
Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
---
Incoming mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.372 / Virus Database: 207 - Release Date: 6/20/2002
---
Outgoing mail is certified Virus Free.
Checked by AVG anti-virus system (http://www.grisoft.com).
Version: 6.0.372 / Virus Database: 207 - Release Date: 6/20/2002
Received on Wed Jul 03 23:58:00 2002
This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:23:57 EDT