RE: ASME BPVC Sec II 1977 Edition

From: <Samuel>
Date: Thu Jul 18 2002 - 12:37:00 EDT

Thanks very much, and Grade WPC for A234. This requirement is used for fit-in-service assessment for BFP discharge nozzle which design temp. was at 400 Deg. F.

Best Regards,

Samuel

-----Original Message-----
From: Christopher Wright [mailto:chrisw@skypoint.com] Sent: Thursday, July 18, 2002 9:30 AM
To: ?
Subject: Re: [PipingDesign] ASME BPVC Sec II 1977 Edition

>Any one has 1977 ASME BPVC Section II, Part D, please help us to check out
>the allowable stress data for A105, A106, and A234.
You don't give up, do you? Ever wondered if no one has the allowables you need? ;->

first--there was no Section II part D in 1977. The allowables were provided in the separate construction sections. The best I can do is 1989, but I'd be willing to bet that it hadn't changed since then

The following apply to temperatures up to 650F for Section VIII Div 1 construction.

A-106 A   12 ksi
A-106 B   15 ksi
A-106 C   17.5 ksi
A-105      17.5 ksi

Too many grades for A-234 to write them all down. If you're interested let me know what grade and the temperature.

Christopher Wright P.E.    |"They couldn't hit an elephant at
chrisw@skypoint.com        | this distance"   (last words of Gen.
___________________________| John Sedgwick, Spotsylvania 1864)
http://www.skypoint.com/~chrisw

Unsubscribe: PipingDesign-unsubscribe@yahoogroups.com

Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/ Received on Thu Jul 18 12:37:00 2002

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:23:57 EDT