Re: PDS experts, HELP!

From: <Paul>
Date: Tue Aug 20 2002 - 23:50:00 EDT

Since it appears to be an ISOGEN issue, you might want to look here: http://www.alias.ltd.uk/isogen.htm

Could the (35:1055), (35:1119),(35:2008),(35:2026), etc, refer to (code line:character/variable)? It's been awhile since I mucked around with code like this.

Otherwise, most of the errors seem to be fairly well explained; invalid or missing data from the main database or too many characters entered by the user for a data field.

Or maybe I just don't know what I'm talking about again.

Paul

> Dear PDS experts,
> Could you tell me how I can figure out where the problem is in the .ERR
> file:
>
> ..............
> ISOGEN INTEL NT VERSION 7.17.9
> (35:1119) WARNING - INVALID DATA FOUND IN DDF(-123) FILE
> - IN SUB SECTION : FITTINGS-UNDIMENSIONED-BRANCHES
> - (35:1038) WARNING - USER DEFINED FITTING NEW KEY
> ALREADY EXISTS
> - OLD SHAPE USED
>
> ERROR DETECTED IN PIPE /06-0P0559-18"-EF8B
> (35:1055) WARNING - INSTRUMENT NAME EXCEEDS BALLOON SIZE
> (35:1055) WARNING - INSTRUMENT NAME EXCEEDS BALLOON SIZE
>
> DRG. 1 /06-0P0559-18"-EF8B
> (35:2008) DATA FAULT SKEW
> PLOTTED
> (35:2026) FAIL
> ................................
>
> Thank you very much and what is the (35:1055) in the file for?
>
> Thanks
>
> Robert Liu
> Piping/Mechanical Designer
> UE-1 Project
> CoSyn Technology
> 1-780-440-7254
> Robert.Liu@UE-1.com
Received on Tue Aug 20 23:50:00 2002