HI ,
Tanmoy ,
The problem of mismatch of reboiler requires
more Details like whether each springs are mounted separately below
reboiler or the common structure is provided below the reboiler to rest on
spring load flange .
Regards,
Rajesh Balapure.
Tanmoy Saha <Tanmoy.Saha@Halliburton.com> on 09/12/2002 05:24:37 PM
Please respond to <a href="/group/PipingDesign/post?postID=jfGZAM8EC9tbgMaZczyGZGzKj9RKy1POznO0cBKdmigQzsMBlWmliyq_g20K1VEg0Vtgy8_FJPnVxc5r0cdoJ4Inf3g">PipingDesign@yahoogroups.com</a>
To: <a href="/group/PipingDesign/post?postID=jfGZAM8EC9tbgMaZczyGZGzKj9RKy1POznO0cBKdmigQzsMBlWmliyq_g20K1VEg0Vtgy8_FJPnVxc5r0cdoJ4Inf3g">PipingDesign@yahoogroups.com</a>
cc:
Subject: [PipingDesign] Column Reboiler problem
Hi all
This is a problem observed and raised by one of my friend. My views are as below
Information is not complete. Further information like full detail of the
column at least the distances of the nozzles from bottom tangent line of
the
column is required.
However it looks like it is not a stress problem as there is mismatch of
two
nozzles. If it was a stress problem both the nozzles should have deflected
same way and there shouldn't have been any relative displacement. Possible
things are
Am I correct? What do you think?
Thanks
Tanmoy Saha
Kellog Brown & Root, Singapore.
Ph. 6422 2535
Email. <a href="/group/PipingDesign/post?postID=o5_xdlrnlvKe-yVkAu_TLQZ9B9byytaQKlFqCuK7FwRfIb34DOJ1C25axsGy7379dL1z4ZdiojAroTlTmIBjBVtqVXI">Tanmoy.Saha@Halliburton.com</a>
Problem:
COLUMN
Reboiler
80" connection
Reboiler
Flange
4 Lugs
2 Springs
per lug
There is a column with a reboiler connection of 80" size. The reboiler is
supported on 4 lugs and there are 2 F type springs below each lug. Each
spring takes a load of about 10 tonnes. The reboiler is very heavy. The
reboiler is supported on a separate concrete structure.
After about 8 years of operation client found out that the 80" connection
nozzle flange and the reboiler body flange were leaking. So to replace the
gaskets the reboiler was disconnected at the the 80" nozzle flange and the
body flange. When they were refitting the removed part of the reboiler back
to the original position, they first connected the 80" nozzle flange. Then
they found out that there was 10 mm gap between the two body flanges.
Nobody is able to guess what happened. The lugs are still touching the
spring load flange. The pointer on the flange is at topmost position and
not
at center.
There are 30" piping connections on the downward part of the reboiler.
Can u suggest any reasons what could have gone wrong ??
[Non-text portions of this message have been removed]