RE: Stress Intensification Factor

From: <Ed>
Date: Wed Oct 09 2002 - 09:11:00 EDT

A few information available in ITT GRINNELL - Piping Design and Engineering.

Stress Intensification Factor depends upon pipe thickness, pipe dia and bend radius.

-----Original Message-----
From: rajeev chaudhari [mailto:rajeevbhai@yahoo.com] Sent: Wednesday, October 09, 2002 7:41 AM To: PipingDesign@yahoogroups.com
Subject: [PipingDesign] Stress Intensification Factor

Dear Members,

  Need info about Piping stress intensification factor. Any thumb rule is there to calculate the SIF at defined interseting point For Example -At elbow or at Pipe to Reducer joint . Is the value depends upon diameter of Pipe?
Factors governing SIF value?

Appreciate your valuable time.

Best Regards
Rajeev



Do you Yahoo!?
Faith Hill - Exclusive Performances, Videos & More http://faith.yahoo.com

Texas Flange - a good source for information on industrial flanges, all they ask is for referrals for designs they help with. 877-610-8924.
www.texasflange.com



unsubscribe: PipingDesign-unsubscribe@yahoogroups.com

Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/ Received on Wed Oct 09 09:11:00 2002