Re: viclaulic coupling

From: <Christopher>
Date: Mon Oct 14 2002 - 10:29:00 EDT

>An audit was
>carried out. It was found that the couplings which were higly loaded gave
>way inspite of the deflections remaining within allowables.
Couple of things. Don't assume that allowable deflection is the same as allowable stress or allowable load. Deflection will govern how seals perform, but allowable loading will affect fatigue behavior in the undercut pipe. People tend to assume that fatigue isn't a problem because most piping codes and Section VIII-1 don't require fatigue analysis. That doesn't mean that fatigue failures can't happen.

Christopher Wright P.E.    |"They couldn't hit an elephant at
chrisw@skypoint.com        | this distance"   (last words of Gen.
___________________________| John Sedgwick, Spotsylvania 1864)
http://www.skypoint.com/~chrisw Received on Mon Oct 14 10:29:00 2002