RE: Clarification needed regarding flange bolt h

From: <Steve>
Date: Sun Mar 09 2003 - 03:12:00 EST


Another way of looking at it is to consider some of the gear we need to bolt up to, especially valves. Flanged valves invariably (I think) have the flange holes straddling the vertical centreline. With wafer valves this is essential to provide a path for the valve stem. If you elect for on centreline bolts, then the valves will have to be mounted at an angle. Pumps has straddled blot holes as well.
All advantages appear to favour straddled holes. I can think of no advantage for on-centreline holes.

Cheers

Steve

-----Original Message-----
From: Christopher Wright [mailto:chrisw@skypoint.com] Sent: Sunday, March 09, 2003 7:00 AM
To: ?
Subject: Re: [PipingDesign] Clarification needed regarding flange bolt h

>Well, there is a couple of reasons for that convention.
I wonder if there might not be another reason--one of those things that may have been important at one time and not now. A bolt on a centerline carries more stress from vertical external loads, like gravity and seismic loading, than if the bolting were to straddle the centerline. In any bolt pattern with radial symmetry (two or more axes of symmetry) the geometric moment of inertia of the pattern is the same about any inplane axis. But the section modulus (moment of inertia /fiber distance) is lowest for the bolt on the vertical centerline, because it's located furthest from the center of the pattern. So the bolt on the vertical centerline carries higher stress from external loading than the rest.

For large diameter flanges with many bolts it really doesn't make much difference because the bolt on the centerline isn't that much further away than the two on either side. (Which also speaks against the 'wrench placement' argument), but for smaller low pressure systems with relatively few flange bolts, straddling centerlines might be considered good practice. On the whole the 'let's all do it one way and straddle centerlines so everything fits' argument stands up better.

Christopher Wright P.E. |"They couldn't hit an elephant at <a href="/group/PipingDesign/post?postID=etlhbbS83zif727Obs7eXFoEesPrHmC6a9rE3L3EN6l6MGSAd_eJWurMip-lhJmv1IGFd7b97DE6">chrisw@skypoint.com</a> | this distance" (last words of Gen.

___________________________| John Sedgwick, Spotsylvania 1864)
<a href="http://www.skypoint.com/~chrisw">http://www.skypoint.com/~chrisw</a>

Discussion List sponsor: The fluid flow calculations website - www.LMNOeng.com - LMNO Engineering,
Research, and Software, Ltd.

unsubscribe: <a href="/group/PipingDesign/post?postID=_C1rJlEaWZpDITfk_5UOvHT4-4kDg6gSy5M_55qkxT0jJSP80d4oFJZCQW1NVP1pkMQbaXxbau7ly5xD4qe7eRRjDJMkNLHxhAV5xBvGEefCHlY">PipingDesign-unsubscribe@yahoogroups.com</a>

Your use of Yahoo! Groups is subject to <a href="http://docs.yahoo.com/info/terms/">http://docs.yahoo.com/info/terms/</a> Received on Sun Mar 09 03:12:00 2003

This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:27 EST