This must be a historical reply for piping design group. I will like to
preserve this mail. And,Thanks for replying on behalf of me from TCL.
Hitesh
Ashok T Dani <ashokdani@tatachemicals.com> on 03/27/2003 01:41:09 PM
Please respond to <a href="/group/PipingDesign/post?postID=ISD3l_prDkSRSDwyAUGpknIF9MaeowSm8lbrAC2VTzfGCuhUVyxgOM6N4p2_h-efXdP2bNDRRCrQboyuuLcvSnLNNg">PipingDesign@yahoogroups.com</a>
To: "'PipingDesign@yahoogroups.com'" <PipingDesign@yahoogroups.com> cc: (bcc: HITESH N PRAJAPATI/L&T-CHIYODA) Subject: RE: [PipingDesign] Re: Minimum distance between Fittings
Thanks, Forum Members...
No matter...after one year...got the answer.....
Regards,
-----Original Message-----
From: tomcruz55 [SMTP:tomcruz55@yahoo.com]
Sent: Thursday, March 27, 2003 12:34 AM
To: <a href="/group/PipingDesign/post?postID=ISD3l_prDkSRSDwyAUGpknIF9MaeowSm8lbrAC2VTzfGCuhUVyxgOM6N4p2_h-efXdP2bNDRRCrQboyuuLcvSnLNNg">PipingDesign@yahoogroups.com</a>
Subject: [PipingDesign] Re: Minimum distance between Fittings
The HAZ width in butt weld joint is very very narrow. So what's with
the 50 mm pup piece? We've welded a pup piece less than this to make
up for the shoratge in the "short lenght" gate valve without a
problem. As long as it pass the NDE and hydro and matl is usitable
for service, chances are your fabricated pipe spool will be OK.
For the criteria related to dimesnion of fabricated spool, ive go
with the PFI Standard.
--- In PipingDesign@yahoogroups.com, "Glenn Dillon"
<glenn.dillon@t...> wrote:
> Hitesh, assume these are butt weld fittings. Fitting to fitting
is
> preferred but where not possible I work on minimum pup spool
distance of 50
> mm to allow for weld effected zone and weld efficiency. Haven't
had any
> failures yet. With steam, elbows can be highly stressed and its
best to
> ovoid short pipe sections and layout distribution to allow fitting
to
> fitting.
>
> Hope these comments of some help. Best regards Glenn
>
> -----Original Message-----
> From: Ashok Dani [mailto:ashokdani@t...]
> Sent: Friday, March 22, 2002 4:29 PM
> To: 'pipingdesign@yahoogroups.com'
> Subject: [PipingDesign] Minimum distance between Fittings
> Importance: High
>
>
>
> > What is the minimum distance required between Bend-Tee or
Tee-Tee
for
> > Steam
> > line or as per B31.1?
> > Thanks in advance
> > Hitesh
>
>
> _____________________________________________________
> Unsubscribe: <a href="/group/PipingDesign/post?postID=IuxjPy3KDq-UwSfe-013U_NyI6o0ZqjkBINlWTUo0ea6F_2aFOfzy5jTQxG40407mWtbbj65yN3_rObt6Hy2ARYKkHHB0J3dBQtx1UFSzh9VZK8">PipingDesign-unsubscribe@yahoogroups.com</a>
>
> Your use of Yahoo! Groups is subject to
<a href="http://docs.yahoo.com/info/terms/">http://docs.yahoo.com/info/terms/</a>
------------------------ Yahoo! Groups Sponsor
=====================================================
Discussion List sponsor: The fluid flow calculations website -
www.LMNOeng.com - LMNO Engineering,
Research, and Software, Ltd.
=====================================================
unsubscribe: <a href="/group/PipingDesign/post?postID=IuxjPy3KDq-UwSfe-013U_NyI6o0ZqjkBINlWTUo0ea6F_2aFOfzy5jTQxG40407mWtbbj65yN3_rObt6Hy2ARYKkHHB0J3dBQtx1UFSzh9VZK8">PipingDesign-unsubscribe@yahoogroups.com</a>
=====================================================