Boo hoo.
Ah sure it was a wild shot,
On another point. Has anyone had success exporting centre lines from AutoPIPE back into AutoPLANT?
I am aware the capabilities of importing from AutoPLANT to AutoPIPE and know it has its limitations but am wondering about the reverse?
Regards
Conor
"Steve McKenzie" <Mechproj@xtra.co.nz>
09/05/2003 18:17
Please respond to PipingDesign
To: <PipingDesign@yahoogroups.com>
cc:
Subject: RE: [PipingDesign] New question; blowing out gaskets on
PE line; how to
Evening Conor
Yes I have one, yes I cant understand a word of it, and no you cant have it.
Cheers
Steve McKenzie
-----Original Message-----
From: conor.walshe@alcan.com [mailto:conor.walshe@alcan.com]
Sent: Friday, May 09, 2003 7:26 PM
To: PipingDesign@yahoogroups.com
Subject: RE: [PipingDesign] New question; blowing out gaskets on PE
line; how to stop
Evening all,
I am trying to locate a copy of "Design of Piping Systems" by M.W. Kellogg There was a also a 1991 edition by John Wiley and Sons Publ
I have managed to locate a copy in the nearby university library but would like a copy for myself. I'd like allot of things but would settle for the book for today...
Anyone biting?
Regards
Conor
"Steve McKenzie" <Mechproj@xtra.co.nz>
09/05/2003 17:21
Please respond to PipingDesign
To: <PipingDesign@yahoogroups.com>
cc:
Subject: RE: [PipingDesign] New question; blowing out
gaskets
and a bloody good flange they are too.
Cheers
Steve McKenzie
-----Original Message-----
From: Geoff Stone DD&D Australia [mailto:blenrayaust@yahoo.co.uk]
Sent: Friday, May 09, 2003 12:06 PM
To: PipingDesign@yahoogroups.com
Subject: Re: [PipingDesign] New question; blowing out gaskets on PE
line; how to stop
Table F was in the British Stand BS 10 before that was superseded. The
Australian Standard AS 2129 still uses the nomenclature. Another standard
AS
4087 duplicates the falnges but designates them by class. They are
peculiart
to
the antipodese.
--- alwyn KAYE <altecheng@primus.ca> wrote:
I once used the appropriate cement for the material and cement welded on
stiffeners the same OD as the joint and circumferentially. Looked horrible
bit
it worked. Its amazing how chunks of the stuff can be molded right on...
almost
any shape
Gents
Have put in a 250NB (355 OD) PN20 PE slurry line; expected max pressure 16
bar. Flanged joints are stub flanges, gramophone finish, Table F steel backing rings. Gaskets are 3mm reinforced insertion rubber. Have had a few
blowouts at 10 bar as we are not yet up to full output. Bolts were not being
tightened properly but I think the problem is more than that.
Need a better gasket.
Have considered:
No gasket; just tighten her up; the slurry solids might blind off any minor
leaks.
CAF gasket. Not my favourite as the CAF is probably too hard for the PE
grooves to get a good bite on.
Spiral wound or corrugated metal.
Metal backing ring to rubber: my favourite but where do you buy them?
Metal ring which cuts into the plastic as the joint is tightened.
Has anyone had this problem and if so how did they overcome it? No time for
major work to the flange faces, so the solution must be with the gasket itself.
In anticipation
Thanks
Steve McKenzie
Yahoo! Groups Sponsor
Research, and Software, Ltd.
Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
[Non-text portions of this message have been removed]
Yahoo! Groups Sponsor
Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
Overseas tel 61 2 402 35 2313 fax 61 2 8850 2313 mobile 0402 35 2313 Mail Address PO Box 1351 Castle Hill NSW 1765 Australia
Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
[Non-text portions of this message have been removed]
Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
Your use of Yahoo! Groups is subject to http://docs.yahoo.com/info/terms/
[Non-text portions of this message have been removed] Received on Sun May 11 20:36:00 2003
This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:24:00 EDT