Re: about check valve

From: <chenysh>
Date: Wed May 28 2003 - 20:36:00 EDT

Dear Geoff,
Thanks for your comments.
yes, the first concept you mentioned is right. In my designing of the Check Valve of the Compressor's export, I likely choose the same rate (e.g CL300RF) Valve with different Export's Pressures (e.g 60 deg.C with 2.0MPa or with 2.5MPa), the Breaking Pressures of two services, theoretically speaking, are not same.
Will the manufacture choose the different Breaking-Bressure on the same rate valve?
Are there some mathematic model to simulate the design of Plate weight (e.g BC-SWING type)?
The problem puzzled me for a long time, please help me in this question.

thanks

regards,
  Chen YS
P.R.China
chenysh@lpec.com.cn Received on Wed May 28 20:36:00 2003

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:24:00 EDT