The cut off for percentage variability of spring is limited to 25 % ( or 50
mm deflection ) industry-wide, except for locations close to strain
sensitive equipments.
Other than that for, non critical locations, why the deflection is
typically
limited to 50MM? If 50 mm does not cause a variability change of more than
25 % in what way can it harm the spring /the system?
Also for critical lines some adopt to restrict variation of the spring to
10 to 15 %
How does it affect the system?
when it is recommended to restrict variation of spring to 10 -15%.
Your comments are appreciated.
Regards,
Rajesh Balapure
Received on Thu Aug 28 07:17:00 2003
This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:29 EST