thanks for yr guide,but about centrifugal compressor whith 4 nozzle?
best regard
ghasemi
George McKinney <gmckinney@augustaeng.com> wrote: Nozzle loads on a multi-stage reciprocating compressor should be checked for each stage. Each stage will have different suction and discharge pressure and temperature. This will result in different forces acting on the cylinder flanges (nozzles).
The compressor manufacturer will give an allowable flange or nozzle rating for his machine. This is usually intended to limit the load which is being applied back through the compressor frame, which would result in deformation, particularly around the compressor crosshead bearing. This is what we are usually trying to limit, to prevent distortion which would cause failure of the crosshead bearing slide. Thus, we are looking at the sum of forces on the suction and discharge nozzle of any particular cylinder, which must be resisted by the compressor frame. As I noted in my previous msg, the nozzle loading will be a sum of both pressure loading and any thermal loading. Normally, the manufacturer should give you maximum allowable values for vertical, horizontal (perpendicular to the crank centerline) and axial loading.
Of course, this relates to forces as limited by the compressor frame itself. It is possible that the compressor pulsation bottle may have some limit on the attachment of nozzle and flange to the bottle. This, of course, would be a matter to take up with the piping/bottle manufacturer.
George McKinney
----- Original Message -----
From: apghasemi
To: <a href="/group/PipingDesign/post?postID=FiMazZeL-imUBoW4GJ7dWjUdZYzc_qfyMfQJgpbjeKigu-SQdZYB7SGycjbM6gp-SdIUO4fr2tRg4VwNcM6A3T9K4g">PipingDesign@yahoogroups.com</a>
Sent: Tuesday, September 23, 2003 2:54 AM
Subject: [PipingDesign] api 617
dear friends
I have studied about this standard(nozzle allowable loads)and i have seen
one dacument from Thermodyn about a compressor with 4 nozzle( 2 inlet and 2
exhuast)and in this dacument each stage shuold be satisfied according to api
617 .
my question is this :should we not check all nozzle load with togethers?
and api617 is for 2 nozzle compressor,isn't it?
is there any guideline about this kind of compressor?
Yahoo! Groups Sponsor
ADVERTISEMENT
========================================
Discussion List sponsor: The fluid flow calculations website - www.LMNOeng.com
- LMNO Engineering, Research, and Software, Ltd.
Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
[Non-text portions of this message have been removed]
Yahoo! Groups SponsorADVERTISEMENT
Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service. reind
[Non-text portions of this message have been removed]
Received on Wed Sep 24 09:11:00 2003
This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:29 EST