What r the reasons you r changing the type of valve? Wafer is used
because of space limitations.
AJ
-----Original Message-----
From: rajendra bajikar [mailto:rajendrabajikar@yahoo.com]
Sent: Wednesday, October 29, 2003 8:40 AM
To: <a href="/group/PipingDesign/post?postID=hDx-u4COhk4Bi3PY0_-EC9UxthwQwz6tu5iksthCmAhK_Lnr5Dm_4U8V6d4pNsSNF4q-x7XW92dNKNGkeoYnNOOD">PipingDesign@yahoogroups.com</a>
Subject: Re: [PipingDesign] check valve
The Non Return Valve, whatever type you use, is to prevent back flow. You may want to check out the pressure losses between the two, if it is critical in any way. You have not mentioned the reason for this change.
Regards,
"Lakshmi V. Narayana" <LNarayana@safco.net> wrote:
Dear friends,
Instead of wafer type check valve(PTFE lined),PTFE ball type check valve
is
being used for oily water service (3"NB) pressure 4KG/cm2 temp 44C . is
there any negative impact in doing so. can anybody throw some light on
this
.
Regards
LAKSHMINARAYAN
MECHANICAL ENGINEER
SAFCO
Your use of Yahoo! Groups is subject to
<a href="http://docs.yahoo.com/info/terms/">http://docs.yahoo.com/info/terms/</a>
Rajendra Bajikar.
[Non-text portions of this message have been removed]
Your use of Yahoo! Groups is subject to
<a href="http://docs.yahoo.com/info/terms/">http://docs.yahoo.com/info/terms/</a>
Received on Wed Oct 29 06:24:00 2003
This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:30 EST