Donot go for Pipe support structure if the height is more. Bending shall be problem apart from heavy pipe Structure. Use Trestle type structure which will have more strength as compared with Single Piped structure in Horizontal direction. It will be lighter structure.Transvers MS Rod or Friction pad with Trestle type structural design could be the better design.
By the way what kind of flare line size, temp & elevation is been under question ?
Regards,
Shashikant Teli

-----Original Message-----
From: Sajit Viswan [mailto:sviswan@tebodin.co.om] Sent: Tuesday, November 11, 2003 2:51 PM To: <a href="/group/PipingDesign/post?postID=XJ2tCpn0reLWa_3PhPNTm-fAxD0d-QaM4y7SIbYqtTFU3un2X_E5sa6hZxHSTChq_CDUAxE4aSztQ6cfsKhxxLrS">PipingDesign@yahoogroups.com</a> Subject: RE: [Man.Distr]Re: [PipingDesign] Piping supports contact surface friction factor

Consider this,

If you use Teflon slides, the weight of steel can be reduced. The gains resulting from using reduced quantity of steel, will it not out weigh the cost of providing the Teflon slides?

It is sometimes done this way, on concrete pipe racks, steel rods are placed in the transverse direction to support the pipes. This will provide a point contact between the pipe and the steel rod.

The friction factor of 0.3 is for normal steel to steel. Sliding friction is not dependent on area of contact. Therefore how the above is effective, perhaps somebody can tell me. It is my guess that it may be because of this. Steel after rusting, if the area of contact is more will stick more together thus requiring a large force for sliding to begin than if it were with a rod.

Sajit

-----Original Message-----
From: k1_m_a [mailto:mashayekh-k@iritec.com] Sent: Tuesday, November 11, 2003 10:58 AM To: <a href="/group/PipingDesign/post?postID=XJ2tCpn0reLWa_3PhPNTm-fAxD0d-QaM4y7SIbYqtTFU3un2X_E5sa6hZxHSTChq_CDUAxE4aSztQ6cfsKhxxLrS">PipingDesign@yahoogroups.com</a> Subject: [Man.Distr]Re: [PipingDesign] Piping supports contact surface friction factor

Dear Sajit,

The history of the job is that, considering the expences, construction concerns and the number of supports we are obliged to use simple pipe supprts made of pipes. And because of this Teflon Sliders can not be used.

And that friction factor of 0.3 has been considered based on Petroleum Standards in my country. But now I am looking for some other standards and reliable references to based on them lower friction factor for pipe to pipe contact can be cosidered.

That's all.

Regards,

Keivan

Yahoo! Groups Sponsor

ADVERTISEMENT <<a href="http://rd.yahoo.com/SIG=12c1fi1tl/M=267637.4116732.5333197.1261774/D=egroup">http://rd.yahoo.com/SIG=12c1fi1tl/M=267637.4116732.5333197.1261774/D=egroup</a> web/S=1705083319:HM/EXP=1068620302/A=1853618/R=0/*<a href="http://www.netflix.com/Def">http://www.netflix.com/Def</a> ault?mqso=60178338&partid=4116732> click here

<<a href="http://us.adserver.yahoo.com/l?M=267637.4116732.5333197.1261774/D=egroupmai">http://us.adserver.yahoo.com/l?M=267637.4116732.5333197.1261774/D=egroupmai</a> l/S=:HM/A=1853618/rand=177805795>



Discussion List sponsor: The fluid flow calculations website - www.LMNOeng.com - LMNO Engineering, Research, and Software, Ltd.

Information presented on this list is given as helpful advice, nonsense, carefully-considered calulation or any combination of the above. The intent is to spark discussion and encourage knowledge-sharing amongst professionals. If you blow yourself up by doing stuff remotely described by info gleaned from reading this list, you are an idiot.

Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service <http://docs.yahoo.com/info/terms/> .

[Non-text portions of this message have been removed]



Discussion List sponsor: The fluid flow calculations website - www.LMNOeng.com - LMNO Engineering, Research, and Software, Ltd.

Information presented on this list is given as helpful advice, nonsense, carefully-considered calulation or any combination of the above. The intent is to spark discussion and encourage knowledge-sharing amongst professionals. If you blow yourself up by doing stuff remotely described by info gleaned from reading this list, you are an idiot.

Your use of Yahoo! Groups is subject to <a href="http://docs.yahoo.com/info/terms/">http://docs.yahoo.com/info/terms/</a>



NOTICE - This communication may contain confidential and privileged information that is for the sole use of the intended recipient. Any viewing, copying or distribution of, or reliance on this message by unintended recipients is strictly prohibited. If you have received this message in error, please notify us immediately by replying to the message and deleting it from your computer.
Received on Tue Nov 11 05:40:00 2003

This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:30 EST