An old reference is Guide for Inspection of Refinery Equipment, Chapter
XVIII-Protection of Idle Equipment, API.
PAN
- In PipingDesign@yahoogroups.com, Md Danish <danish_petro@y...>
wrote:
> Dear All,
> Do anyone know the process of mothballing the stippers, Exchangers
and Pupms to use it as a standby to be used during the shutdown of
another plants.
> Thanks & Regards,
> Md Danish
> Process Piping Engineer
>
>
>
> Md Danish
> (Pipeline Division,Radicon)
> RGP consult,P.O. Box no 684,
> Al Khobar 31952,K.S.A
> mobile 057441206
>
> ---------------------------------
> Do you Yahoo!?
> Yahoo! Hotjobs: Enter the "Signing Bonus" Sweepstakes
>
> [Non-text portions of this message have been removed]
Received on Mon Jan 12 21:20:00 2004