TC can be found in ASME IID - Table TCD. It varies with temperature.
For a plain carbon steel, material group A, it varies between 35.1 BTU/hr-ft-°F at 70°F and 15.7 BTU/hr-ft-°F at 1500°F
Barbara
-----Original Message-----
From: k1_m_a [mailto:k1_m_a@yahoo.com]
Sent: 18 February 2004 08:23
To: <a href="/group/PipingDesign/post?postID=GUtfQgI_Gk1BjhZ6loSlrm2KSnJuRozmeHRVCPnlM-QqH_6k99xTVtgAI2AkXzaVJDxd3m09MomGnsy02nVvNUcI9fPhMg">PipingDesign@yahoogroups.com</a>
Subject: [PipingDesign] ASTM A671-CC65 Thermal conductivity
It's most appreciated if somebody could help me fnding Thermal Conductivity of ASTM A671-CC65.
Regards,
Keivan