Hi Arturo, I have used tables in the ammonia refrigeration industry for so long
that I often forget that the pipe thickness can be calculated. In our industry
we use schedule 80 for 1-1/2" and below, schedule 40 for 2" thru 10" and
standard weight for 12" and above. Most of the criteria for the pipe thickness
was derived from B31.5 refrigeration piping standard.
I believe that price drives this thinking on the 14" standard pipe. Last time I priced 14" standard pipe was cheaper than 14" schedule 30 because schedule 30 was not stocked.
Anyways, I found a new table that was published by the International Institute of Ammonia Refrigeration (IIAR) www.IIAR.org that is similiar to the table I use an is more official. The table is from the IIAR Ammonia Refrigeration Piping Handbook, Table 1-21 and it states that a "corrosion allowance is included for threaded or welded piping, equal to the depth of a pipe thread". The IIAR piping handbook is an excellent source of information and I would suggest it as a first buy book for anyone sizing ammonia refrigeration systems.
Gary Gneiting
"Arturo M." <amurillo@t-visa.com.mx> wrote:
Hello all.
There is an Ammonia Industrial Refrigeration system, with a low pressure side (Receiver and evaporator) and works about at 200 psi, we specified a 14" seamless STD pipe carbon steel A-106 gr X42 ( wall 0.375" ) .
Someone is argued that a minimum of Schedule 40 pipe is needed at ( wall 0.438" ), temperature pressure is not a problem he said , Corrosion is the thing to watch out.
So the question is, where can I find the standard norm for correction for corrosion for industrial ammonia for the pipe wall? ( the factor I used was 1/64" ) .
Thank you.
Arturo Murillo.
[Non-text portions of this message have been removed]
To visit your group on the web, go to: <a href="http://groups.yahoo.com/group/PipingDesign/">http://groups.yahoo.com/group/PipingDesign/</a>
To unsubscribe from this group, send an email to: <a href="/group/PipingDesign/post?postID=M3fyKceSdV8L5QJ4jbPn_SE8ZLcVtm1Ova7e1xun__74Fa_JI8OZjn4VJdbJcs-ZLpRlLFwOnS54VOF5z9CZuLYCCiIdSWySHFSvirRkAg">PipingDesign-unsubscribe@yahoogroups.com</a>
Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
[Non-text portions of this message have been removed]
Received on Mon Apr 19 18:11:00 2004
This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:33 EST