Re: Banching from pipes

From: <Christopher>
Date: Tue May 04 2004 - 11:44:00 EDT


>By a comparison between direct pipe to pipe connection and making use of
>fittings or self reinforced fittings for taking branch ,it goes without
>saying that the quality and easiness of the job would be much better in
>the latter case but regarding cost the former would be cheaper.
I haven't done any real estimating for years, but it's hard to imagine that the hand fit-up work would be enough cheaper to justify the likelihood of poorer quality welding. I think if it were truly cheap enough, it's because someone's taking liberties with weld quality. A welded tee requires 3 girth welds, but they're straightforward butt welds with minimal fit-up.

If I understand you correctly, a 'direct pipe to pipe connection' means a hole manually burned in the run, and the branch hand burned and ground to the contour of the run. If the joint isn't fit up properly it will be a starting point for a fatigue or corrosion failure, and if it isn't cleaned up with no protruding edges, it'll be a mess for fluid flow. My own opinion is that if such an operation truly is cheaper, it's because weld quality is compromised, and that isn't really cheaper at all