From: <Aaron>
Date: Fri May 21 2004 - 09:45:00 EDT


Ken,

In my experience the clamps hold up well to thermal expansion....If the line is designed with sufficient change of direction to handle the force. The MHP style could be used in high pressure situations. But over time they just leak. I work in mostly bio-pharm systems. And the places where clamps are required are for removable spools for sterilization, calibration of an instrument, or connection to a piece of equipment. It is standard practice to minimize the use of such clamps because like I said, eventually they just leak. This is due to the gasket being repeatedly fatigued by clamping and unclamping. A quick replacement and they are good for another round. Being Autoplant users, we use AutoPIPE for the "stress test" and it seems to handle the clamp fitting just fine.

Regards,

Aaron Wolfe
Piping Designer
Paul Mueller Company
P.O. Box 828
Springfield, Mo 65801
(417) 575-9780
E-mail: <a href="/group/PipingDesign/post?postID=Xx9MXRIulWgh7Xa7DrgfzY4dY_sqMoEBfvJOs2ioWXU1ZeLELwqojvWEcL6SvantSn_561WAqw">awolfe@muel.com</a>

-----Original Message-----
From: Ken Nisly-Nagele [mailto:knislynagele@applied-e-s.com] Sent: Thursday, May 20, 2004 5:43 PM
To: <a href="/group/PipingDesign/post?postID=HkXeO-dh4zioe7ds6dhGkjl-T2lZ9pHqtLgRd1kqje1peYn1bnSihcbjo0s1-jXxNIMG1MlodsPr8x90rjIqY0Kp3ow">PipingDesign@yahoogroups.com</a> Subject: RE: [PipingDesign] Modeling Hygienic Unions

These clamps are made by Tri-Clover, Waukesha, or Swagelok, and are rated to
200 psig. By meeting code, I mean to demonstrate that the unions will not
leak during sterilization. I'm not concerned about the clamps working at
the design pressure, but rather, I'm concerned with the clamps leaking when
the piping in which they are installed undergoes bending during thermal expansion and causes the faces of the ferrules to spread apart and result in
leakage. With standard flanges there are tools to predict leakage, but I am
not aware of a way to check for leakage with a union of this type. It may
be that the only solution is to ask the manufacturers to test and publish
the data as a group or individually.

Ken A. Nisly-Nagele, P.E.
Project Engineer, Mechanical
Applied Engineering Services, Inc.
7999 Knue Road
Indianapolis, IN 46250
317-585-8920

-----Original Message-----
From: Christopher Wright [mailto:chrisw@skypoint.com] Sent: Thursday, May 20, 2004 5:00 PM
To: ‡
Subject: RE: [PipingDesign] Modeling Hygienic Unions

>My apologies, my initial posting was not sufficiently clear.
No problem. Are you talking about clamps like the Grayloc or Tri-Clover variety?

>The question is one of
>applying the unions and demonstrating compliance with the code.
I think the easy for doing this is to show that your clamp meets the code
rules for a pressure which produces a unit axial load equal to the (calculated axial pressure stress + the calculated bending stress)/pipe wall thickness. This is fairly conservative, but it'll meet the U-2(g) requirements without a lot a extra work.

Christopher Wright P.E. |"They couldn't hit an elephant at <a href="/group/PipingDesign/post?postID=31Nh9Ss0VQWLuBPZxu1YFDJ2BPyiiS3WXmm4ukCpxOhMdMeB1BAwoBblS4Wk3Ke7CNkW_w0ovkzGXg">chrisw@skypoint.com</a> | this distance" (last words of Gen.

___________________________| John Sedgwick, Spotsylvania 1864)
<a href="http://www.skypoint.com/~chrisw">http://www.skypoint.com/~chrisw</a>

PipingOffice - Excel Spreadsheets for Piping Calculations <a href="http://www.pipingoffice.us/">http://www.pipingoffice.us/</a>

Main site: <a href="http://www.pipingdesign.com">http://www.pipingdesign.com</a>

Yahoo! Groups Links



PipingOffice - Excel Spreadsheets for Piping Calculations <a href="http://www.pipingoffice.us/">http://www.pipingoffice.us/</a>

Main site: <a href="http://www.pipingdesign.com">http://www.pipingdesign.com</a>

Yahoo! Groups Links Received on Fri May 21 09:45:00 2004

This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:34 EST