The loads we get out of Caesar-II, assume that only piping will move in case of seismic but the structure or equipment where the supports are attached are not moving. Isn't this an impractical assumption?? In case of seismic, won't the piperack or vessel will also move with the piping?? If we use these loads, it leads to overdesign.
However nobody want to take risk, and hence everybody prefers to design the structure to these loads and not the REAL loads that may occur. Also the complications to arrive at such loads is very difficult. There are no std formulas and only the thumb rules or guess will have to be used.
Best Regards.
Tushar Zope
Extn: 162
"Rahul Kulkarni"
<rdk77@yahoo.com> To:
<a href="/group/PipingDesign/post?postID=zZfglIA_ncJ-nlpBAmwFlLljD0KJ9c2OW4lhNsbA7vDAkl9T19qffrZeZdflqiNL5v_Ah1w8M1cPHUaww53Zq3RpU1Ur2A">PipingDesign@yahoogroups.com</a>
cc:
06/03/2004 03:14 Subject: Re: [PipingDesign]
Longitudianal Seismic Loads on Pipe Anchors Bay.
PM
Please respond to
PipingDesign
Hi
Everything depends on what type of piping you are doing.
It is better to add the sysmic load while designing the anchor.
Rahul
RAHUL DEEPAK KULKARNI
GHARKUL 36 MANISHANAGAR
PANDHARPUR
PIN 413304
[Non-text portions of this message have been removed]
Yahoo! Groups Sponsor
ADVERTISEMENT
click here
Yahoo! Groups Links
To visit your group on the web, go to:
<a href="http://groups.yahoo.com/group/PipingDesign/">http://groups.yahoo.com/group/PipingDesign/</a>
To unsubscribe from this group, send an email to:
<a href="/group/PipingDesign/post?postID=BJnUFF5qk4GLWgmAWChA4RoCsMGtbzl6VeTBXKb8-3-FeUaF8Jte-fq6CN1tjKrJnA7Smat3ngYD0yVz5vGyjVILRBFtO4Z8-bspn_Qv">PipingDesign-unsubscribe@yahoogroups.com</a>
Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
=======================================================
Confidentiality Notice
This communication and the information it contains:-
(a) Is intended for the person(s) or organisation(s) named above and for no
other person(s) or organisation(s).
(b) May be confidential, legally privileged and protected in law. Unauthorised
use, copying or disclosure of any of it may be unlawful. If you have received
this communication in error, please contact us immediately by email at
<a href="/group/PipingDesign/post?postID=f4wCuX5hWuke-clwW5bm0_kIQn829y4sUCmeJroJoV8Md0q1-POkw43pSF-4jLzuo1-sRT5i0yqxq_hIP3YlHtqA">Postmaster@fwuk.fwc.com</a>.
This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:34 EST