Re: Pipe Pressure

From: <cckla>
Date: Sun Jun 13 2004 - 03:38:00 EDT


Christopher Wright,

Thank you for your information.

Regards,
cckla

>Is this pressure valid only for the pressure acting from internal only ?
Yes. External pressure involves potential stiffening rings and buckling
response. The pressure that is designed for is the pressure difference
across the pipe wall. If you had 250 psig inside and 100psig outside, the
design pressure would be 150 psi internal pressure. Note that if you ever
had the 250 psi acting alone, with only atmospheric pressure on the
outside, you'd have to design the pipe for 250 psi.

You'd do well to study up on this stuff if you're going to be doing
piping calculations or reviewing them. This is a basic principle.

Christopher Wright P.E. |"They couldn't hit an elephant at
chrisw@skypoint.com | this distance" (last words of Gen.
___________________________| John Sedgwick, Spotsylvania 1864)
<a href="http://www.skypoint.com/~chrisw">http://www.skypoint.com/~chrisw</a>



PipingOffice - Excel Spreadsheets for Piping Calculations
<a href="http://www.pipingoffice.us/">http://www.pipingoffice.us/</a>


Main site: <a href="http://www.pipingdesign.com">http://www.pipingdesign.com</a>

Yahoo! Groups Sponsor
ADVERTISEMENT


Yahoo! Groups Links

a.. To visit your group on the web, go to:
<a href="http://groups.yahoo.com/group/PipingDesign/">http://groups.yahoo.com/group/PipingDesign/</a>

b.. To unsubscribe from this group, send an email to:
<a href="/group/PipingDesign/post?postID=Qx-8ERI8nYQzHMKed6X9u3L-YXCXRnq79_E9JnZWB-nbIHycFCv7Z2xKi9ibXNTdo-RVuO4GuWYe5dDOT2-gHyArtlv_hPAxZl72n2AaOoc">PipingDesign-unsubscribe@yahoogroups.com</a>

c.. Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.

[Non-text portions of this message have been removed] Received on Sun Jun 13 03:38:00 2004

This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:34 EST