Re: LIQUID HOLD UP CALCULATIONS IN PIPELINE OF 3 PHASE FLOW

From: <whasan>
Date: Thu Jul 15 2004 - 23:25:00 EDT


Good day Aziz,

You need of course detailed composition for 3 phase calculations and hold up.as well as hydraulics .a good software is PIPESYS,which comes either part of Hysys package..or as a separate program ,the company is (NEOTEC) There are ofcourse many text books that tackle 2-Phase flow (liquid-gas )..You can start with GPA ( Gas Processors Association ) Handbook

I hope this helps

Regards,

Waiel Hasan
Kemproserv Inc
Canada
----- Original Message -----
From: "Vayani, Aziz (Zeeshan Engineering)" <VayaniA@bp.com> To: <PipingDesign@yahoogroups.com> Sent: Monday, July 12, 2004 12:29 AM
Subject: [PipingDesign] LIQUID HOLD UP CALCULATIONS IN PIPELINE OF 3 PHASE FLOW
> Good Day
>
> I am working on an assignment to calculate the liquid Hold-up in a 12" dia
& 85,000 ft long pipeline that handle three phase flow i-e condensate, water & gas. Any body know about manual calculation or a software that can calculate it.
>
> Thanks
> A. Aziz Vayani
>
>
>
>
>
> =========================================
> PipingOffice - Excel Spreadsheets for Piping Calculations
> <a href="http://www.pipingoffice.us/">http://www.pipingoffice.us/</a>
> =========================================
> Main site: <a href="http://www.pipingdesign.com">http://www.pipingdesign.com</a>
>
> Yahoo! Groups Links
>
>
>
>
>
>
Received on Thu Jul 15 23:25:00 2004