RE: When Flexibility Analysis is Needed?

From: <Ken>
Date: Fri Jul 16 2004 - 09:32:00 EDT

DEEPAK - My understanding is that for compliance with B31.3, all systems require a flexibility analysis unless the system duplicates a successfully operating system, can be judged adequate by comparison with previously analyzed system or are within the limits of Paragraph 319.4.1.

Ken A. Nisly-Nagele, P.E.
Project Engineer, Mechanical
Applied Engineering Services, Inc.
7999 Knue Road
Indianapolis, IN 46250
317-585-8920

-----Original Message-----
From: GET Mithapur [mailto:getuser@tatachemicals.com] Sent: Friday, July 16, 2004 6:02 AM
To: 'pipingdesign@yahoogroups.com'
Subject: [PipingDesign] When Flexibility Analysis is Needed?

Dear All,

Can anybody tell us when Piping Flexibility Analysis is needed? I have referred B.31.3 & B31.1 (clause 319.4.1 & 119.7.1) but not reached any clear conclusion.

What are criteria involved for Piping Stress Analysis. Are there any minimum requirements to be considered while deciding for Flexibility Analysis?

DEEPAK



PipingOffice - Excel Spreadsheets for Piping Calculations http://www.pipingoffice.us/

Main site: http://www.pipingdesign.com

Yahoo! Groups Links Received on Fri Jul 16 09:32:00 2004