Dear Friends
> Although it is difficult to assess the case without having all the
details
> like P&ID, fluid properties etc. the first thing which comes to my mind is
> that due to reduced flow rate of recycled gas from RG Compressor there
could
> be possibility of slug formation in the lines upstream and downstream of
> trim cooler which could be a possible cause of this problem. Slug
formation
> as u know, depend on flow rate,density among other parameters.
>
> Regards
> S.N.Singh
>
>
Received on Thu Aug 26 00:49:00 2004