RE: 90.08 degree elbow?

From: <Al>
Date: Fri Sep 17 2004 - 19:16:00 EDT


i'm sure theres lots of such stories, with no budget I checked some pipeline drawings submitted for analysis and found the pipeline (per the dwgs) missed the station it was supposed to enter by 567m.. they were told the pipeline had to end at the meter station, so it did by the lines just not by the numbers

-----Original Message-----
From: Steve McKenzie [mailto:mechproj@xtra.co.nz] Sent: Friday, September 17, 2004 4:30 PM To: <a href="/group/PipingDesign/post?postID=iGwo53fEM6ma_C4Gk2aEWo9TBuFv0v2K1KdNaYJn2qDahAxQbrgAwchbeEJ3oGa4pI48_N8qnFlTAkcjDeJu1bxcRA">PipingDesign@yahoogroups.com</a> Subject: RE: [PipingDesign] 90.08 degree elbow?

Reminds me of one of my favourites.

I was designing a pump station in Manila a few years back. The station had to fit between an existing street and an existing 500,000m^3 reservoir ; a very tight fit. The CAD guys produced a beautiful layout that looked too good to be true. I took them to site to check measure, and the reservoir was 3m closer to the road than on their drawings. When questioned as to how this happened, they said they were having difficulty getting the pump station to fit, so they "moved" the reservoir on paper. And they couldn't understand why smoke was coming out of my ears.

Cheers

Steve

-----Original Message-----
From: Christopher Wright [mailto:chrisw@skypoint.com] Sent: Saturday, September 18, 2004 10:10 AM To: <a href="/group/PipingDesign/post?postID=iGwo53fEM6ma_C4Gk2aEWo9TBuFv0v2K1KdNaYJn2qDahAxQbrgAwchbeEJ3oGa4pI48_N8qnFlTAkcjDeJu1bxcRA">PipingDesign@yahoogroups.com</a> Subject: Re: [PipingDesign] 90.08 degree elbow?

On Sep 17, 2004, at 4:59 PM, Rich Scotti wrote:

> There is a way to connect two components in AutoPLANT that are not
> completely aligned.

Ah... good plan. Force it to happen with CAD software, thus ensuring that it will happen in the real world. Good thinking. You'll go far in management.
Christopher Wright P.E. |"They couldn't hit an elephant at <a href="/group/PipingDesign/post?postID=yWgQFV2FTaEesK0yVEgJe4kfdIrpuSi5XFAxpgjW47M_Dta_SJDKhXFYhd69qtTlL90v62FEeRAg">chrisw@skypoint.com</a> | this distance" (last words of Gen.

...................................| John Sedgwick, Spotsylvania 1864)
<a href="http://www.skypoint.com/~chrisw">http://www.skypoint.com/~chrisw</a>

PipingOffice - Excel Spreadsheets for Piping Calculations
<a href="http://www.pipingoffice.us/">http://www.pipingoffice.us/</a> =========================================
Main site: <a href="http://www.pipingdesign.com">http://www.pipingdesign.com</a>

Yahoo! Groups Links



PipingOffice - Excel Spreadsheets for Piping Calculations <a href="http://www.pipingoffice.us/">http://www.pipingoffice.us/</a>

Main site: <a href="http://www.pipingdesign.com">http://www.pipingdesign.com</a>

Yahoo! Groups Links Received on Fri Sep 17 19:16:00 2004

This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:10 EST