RE: dynamic stress analysis .

From: <Umapathy>
Date: Wed Dec 29 2004 - 00:37:00 EST


For Static loading the Design factor of safety: 60% of Yield stress is considered and for dynamic loading it would be 35% to have a life of 1 million cycles or more.

Uma

-----Original Message-----
From: gautam wayse [mailto:captain_wayse@yahoo.co.in] Sent: Tuesday, December 28, 2004 05:55
To: <a href="/group/PipingDesign/post?postID=FnsvuYbhfWu-ZfvBugB_mtXUwZ-cOcgwzUxW5tt9IZ70Iar7hq4LaXOUsBrifdQimi0aa7p1aL9Jo5gBuZNGRQnATInW">PipingDesign@yahoogroups.com</a> Subject: [PipingDesign] dynamic stress analysis .

dear friend
if some one working on dynamic analysis and having expertise in same .please solve my fallowing problems .
why it is essential to perform modal frequency response and time histry analysis .
how much differece (in per cent )one can expect in calculated stress
value at static condition and dynamic cases.

gautam wayse



Yahoo! India Matrimony: Find your life partner online Go to: <a href="http://yahoo.shaadi.com/india-matrimony">http://yahoo.shaadi.com/india-matrimony</a>

PipingOffice - Excel Spreadsheets for Piping Calculations <a href="http://www.pipingoffice.us/">http://www.pipingoffice.us/</a>

Main site: <a href="http://www.pipingdesign.com">http://www.pipingdesign.com</a>

Yahoo! Groups Links Received on Wed Dec 29 00:37:00 2004