pulsation damber

From: <Sakir>
Date: Wed Mar 23 2005 - 01:23:00 EST


The matter is regarding one desalination plant High pressure pump.I have some problem with the pulsation damber before the triplex Highpressure pump.The bladder of the pulsation damber was broken so that we replaced it with by puting a blind same like pulsation damber.But the problem is that after some time the plant begins vibrate due to the trapped air inside..So is there is any ther solution as this type of damber is not available in the market. Received on Wed Mar 23 01:23:00 2005