Re: Flat end for piping in creep range

From: <Christopher>
Date: Fri Apr 22 2005 - 10:19:00 EDT

On Apr 22, 2005, at 12:56 AM, Dragos Aron wrote:

> I have an question refer to EN 13480-3:2000. Why the flat end with a
> stress
> relief groove is prohibited for piping in the creep range (7.2.3.4)?
Probably because the stress concentration at the groove results in unacceptable permanent deformation
Christopher Wright P.E. |"They couldn't hit an elephant at chrisw@skypoint.com | this distance" (last words of Gen.

.......................................| John Sedgwick, Spotsylvania
1864)
http://www.skypoint.com/~chrisw/ Received on Fri Apr 22 10:19:00 2005

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:24:07 EDT