RE: Bolting and Valve Length Question

From: <Dennis>
Date: Fri May 27 2005 - 20:59:00 EDT


Paul,

I had this problem once before. We had special nuts manufactured, three times the height of a standard nut, and used these in the middle of the wafer check to join short stud bolts together.

Regards
Dennis Kirk-Burnnand B.E. (Mech)
DENNIS KIRK ENGINEERING
<a href="/group/PipingDesign/post?postID=kTYMkb6hxMUryPB-Ts1mD_FdcIPE9sULFeFC2MvMrwBF-IOl9CzV7L9MvWK2_o3KC5fgQ4BEQ7koqjr-Hy48DrU">denniskb@ozemail.com.au</a> www.ozemail.com.au/~denniskb

-----Original Message-----
From: <a href="/group/PipingDesign/post?postID=rZgl-ySfNUhEjJ8fXyZ7jiiHkzxBRksfmDIWhrq3UWVL7fLBYZb0ftSRT8P2NsgoL5_ZxFSPjNWlKMfd57oYw-yLj_Zt">PipingDesign@yahoogroups.com</a> [mailto:<a href="/group/PipingDesign/post?postID=rZgl-ySfNUhEjJ8fXyZ7jiiHkzxBRksfmDIWhrq3UWVL7fLBYZb0ftSRT8P2NsgoL5_ZxFSPjNWlKMfd57oYw-yLj_Zt">PipingDesign@yahoogroups.com</a>]On
Behalf Of Paul Bowers

Sent: Saturday, 28 May 2005 8:17 AM
To: <a href="/group/PipingDesign/post?postID=rZgl-ySfNUhEjJ8fXyZ7jiiHkzxBRksfmDIWhrq3UWVL7fLBYZb0ftSRT8P2NsgoL5_ZxFSPjNWlKMfd57oYw-yLj_Zt">PipingDesign@yahoogroups.com</a>
Subject: Re: [PipingDesign] Bolting and Valve Length Question

Thanks again Steve, good advice even though I'm being a bit flippant and
trollish below.

There is a 90 degree elbow directly connected to the flange, so there is
possible interference. A scale Autocad drawing makes this obvious, but
the "double curve" of the ell makes it hard to tell if things will fit.

Maybe I need FEA software.

Paul

Steve McKenzie wrote:

> Hi Paul
> if you are stuck for space, there is a type of valve that may help. It
> is used as the main isolator on some steam turbines and functions as a
> (swing) check and an isolator in one. It looks a bit like a tilt check
> with a screwed shaft that forces the disc onto its seat. Often called
> CIES (combined isolating and emergency stop) valve.
> However it wont help if the purpose of the gate is maintenance isolation
> for the check.
> You don't need through bolts to do what you intend; just bolt through
> one side of the gate, bridge the check and bolt up to the pipe flange.
> You should have enough space for that as you only need nut depth plus
> washer plus a few thread turns on each of the gate flange bolt holes.
> The check will not last very well though, as it will see the turbulence
> from the gate trim.



PipingOffice - Excel Spreadsheets for Piping Calculations
<a href="http://www.pipingoffice.us/">http://www.pipingoffice.us/</a>


Main site: <a href="http://www.pipingdesign.com">http://www.pipingdesign.com</a>

--

Yahoo! Groups Links

a.. To visit your group on the web, go to:
<a href="http://groups.yahoo.com/group/PipingDesign/">http://groups.yahoo.com/group/PipingDesign/</a>

b.. To unsubscribe from this group, send an email to:
<a href="/group/PipingDesign/post?postID=oPlMNOgxsv9ax1QYtD0GH8Gh58UXUcXe7ot39Xuo9uDXpo56qFe6ysoNFHjobtRuLrYLY3JTbXf7Nl9awYuE_R88AtWZ6PZD69zxUmtR_74o2g">PipingDesign-unsubscribe@yahoogroups.com</a>

c.. Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
[Non-text portions of this message have been removed]
Received on Fri May 27 20:59:00 2005

This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:41 EST