On Sep 14, 2005, at 3:39 PM, Christopher Wright wrote:
> I couldn't stand it, I wasted 20 minutes or so making a brief
> assessment of what kind of pressures you'd have to build up to bulge a
> doubler plate.
One last thing-- Section VIII UW-15(d) requires that reinforcing pads have a telltale hole to check the soundness of the welds joining the nozzle to the vessel wall. No mention of gas or air or water trapped in the space. The hole can be plugged in service but not with anything that can sustain pressure between the plate and the wall of the vessel. Even a pinhole leak in a nozzle weld could pop off a reinforcing pad.
Christopher Wright P.E. |"They couldn't hit an elephant at chrisw@skypoint.com | this distance" (last words of Gen.
.......................................| John Sedgwick, Spotsylvania1864)
This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:24:09 EDT