Re: SR criteria

From: <prashant480977>
Date: Fri Sep 23 2005 - 00:00:00 EDT


Dear Rakesh,

SR criteria will vary as per the standard used by the professional & nature / type of piping. Basically SR will be done as per -

As per 31.3 SR reqd if PWT is equal or greater than 19.1 mm. As per 31.4 & 31.8 SR reqd if PWT is equal or greater than 32 mm. As per DNV standard SR reqd if PWT is equal or greater than 44 mm.

Regards,
Prashant.

> Disclaimer : This email and any files transmitted with it are
intended
> solely for the use of the addressee(s) only and may contain
confidential
> and/or privileged information. If you are not the addressee, then
this
> message is not intended for you and be advised that you have
received this
> email in error and that any use , dissemination , forwarding,
printing or
> copying of this email is strictly prohibited. In such case
please notify
> the sender and delete this email and any attachments with it from
your
> system immediately.Receipt of this email by you shall not give
rise to any
> liability on the part of Larsen & Toubro
Limited
>

>
> [Non-text portions of this message have been removed]
Received on Fri Sep 23 00:00:00 2005

This archive was generated by hypermail 2.1.8 : Tue Mar 04 2008 - 11:40:44 EST