RE: discharge valve of pumps

From: <Erik>
Date: Mon Oct 17 2005 - 14:21:00 EDT

When the discharge line is full you can start a pump with the valve open. When the line is empty you should start with the discharge valve closed otherwise the flow at startup is too high and there is also a risk of waterhammer the moment the line is completely filled.

Pumps in parallel operation are usually installed with a check-valves at the discharge side. When there are no check-valves an automatic operating valve is used to prevent pumping fluid from one pump through the other pump.

Erik


Van: PipingDesign@yahoogroups.com [mailto:PipingDesign@yahoogroups.com] Namens VIJAYAN PULIKKATH
Verzonden: Monday, October 17, 2005 7:21 AM Aan: PipingDesign@yahoogroups.com
Onderwerp: [PipingDesign] discharge valve of pumps

From: Vijayan Pulikkath
Location: Consultants, Chennai, India
Asst Design Engr

  1. Which is the natural position for a discharge valve of a pump when the pump is started?

    valve open
    valve closed
2) Reason?

3) Is it normal to have an interlock for pump start/stop with the discharge valve when they are operating in parallel and on auto standby? Is it essential?

Vijayan



Yahoo! Music Unlimited - Access over 1 million songs. Try it free.

[Non-text portions of this message have been removed]



PipingOffice - Excel Spreadsheets for Piping Calculations http://www.pipingoffice.us/

Main site: http://www.pipingdesign.com

SPONSORED LINKS Mechanical
<http://groups.yahoo.com/gads?t=ms&k=Mechanical+engineering+jobs&w1=Mechanic
al+engineering+jobs&w2=Cad+drafter&w3=Process+piping&w4=Mechanical&c=4&s=86& .sig=eJlTt13AisXBJmj5Yd3gpA> engineering jobs

Cad
<http://groups.yahoo.com/gads?t=ms&k=Cad+drafter&w1=Mechanical+engineering+j
obs&w2=Cad+drafter&w3=Process+piping&w4=Mechanical&c=4&s=86&.sig=vvtOzHLmT18 e_QbAWxTkqw> drafter

Process
<http://groups.yahoo.com/gads?t=ms&k=Process+piping&w1=Mechanical+engineerin
g+jobs&w2=Cad+drafter&w3=Process+piping&w4=Mechanical&c=4&s=86&.sig=I5RWrbfa QuXyAXwIwxmu0g> piping

Mechanical
<http://groups.yahoo.com/gads?t=ms&k=Mechanical&w1=Mechanical+engineering+jo
bs&w2=Cad+drafter&w3=Process+piping&w4=Mechanical&c=4&s=86&.sig=7WtmMVWyA0yY VZsyGxvDoA>


YAHOO! GROUPS LINKS

[Non-text portions of this message have been removed] Received on Mon Oct 17 14:21:00 2005

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:24:09 EDT