Re: Fram Lewis Filters

From: <Geoff>
Date: Thu Oct 27 2005 - 17:54:00 EDT

Chris,

The test presure is on the nameplate as is the working pressure. The problem is that the surge analysis has shown higher prerssures than the working pressure. It is thought that when the facility was built in the 1960's no surge analysis was done. The operators and owners have not gone back and re engineered the facility. It is only now when a new supplier wants to come on line that the surge analysis has been done.

I think this is a pre existing condition for the current operators. they have been blissfully unaware of non compliance.

My question is what would be the allowable pressure, including surge, according to ASME for this filter? I was thinking that the design pressure would be higher than the working pressure?

Geoff

Christopher Wright <chrisw@skypoint.com> wrote:

On Oct 27, 2005, at 2:43 AM, Geoff Stone DD&D Australia wrote:

> I am based in Australia. I have Fram Warner Lewis filters with the
> following reference

You might want to try wading through the Fram web site <http://www.fram.com/>. I tried a search on Warner Lewis and got a lot of hits but nothing I recognized right away (sorry--short attention span) as a manufacturer. Try it--your mileage may vary.

My experience is that getting design information may be a problem unless you're a big customer. Most manufacturers view all such things as proprietary including the pedestrian stuff that anyone could do if they felt like it. If the filter is meant to be a stationary installation with a significant volume, it may have had to demonstrate compliance with ASME code here in the states at some point. The fact that there's a published test pressure that's 1.5 times the working pressure is an indication that someone was thinking about the ASME Code when it was designed. If the filter were in full compliance, it would carry a code plate welded or perhaps stuck to the body of the filter. How do you know what the test pressure is? Is there some kind of document you could trace back?
Christopher Wright P.E. |"They couldn't hit an elephant at chrisw@skypoint.com | this distance" (last words of Gen.

.......................................| John Sedgwick, Spotsylvania
1864)
http://www.skypoint.com/~chrisw/

PipingOffice - Excel Spreadsheets for Piping Calculations http://www.pipingoffice.us/

Main site: http://www.pipingdesign.com

YAHOO! GROUPS LINKS      Visit your group "PipingDesign" on the web.

     To unsubscribe from this group, send an email to:   PipingDesign-unsubscribe@yahoogroups.com

     Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.


Design Detail and Development (a division of Blenray Pty Ltd)

Mail Address PO Box 1351 Castle Hill NSW 1765 Australia Tel Mob 0402 35 2313 Office 02 8850 2313 AH 02 8850 2324
We specialise in pipe network and waterhammer analysis, pipe stress analysis, the design of buried pipelines and thermoplastic pipe systems.

[Non-text portions of this message have been removed] Received on Thu Oct 27 17:54:00 2005

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:24:09 EDT