Dear friends,
DP=314000 KPa
DT=130C
Line Class 2500
Flange Material: Sa-182 gr F51 (UNS S31803)
Bolt Material SA-193 Gr B7
I performed the Flange Leakage Calculation Using CAESER-II.
The results say the flange joint is leaking/unsafe.These calculation are done by ASME Sec VIII div 1 Appendix-2 & S
Now If want to make my system Safe what I had to do
Please guide me of the economical alternatives. Is there any website which gives the ID and OD of raised face of flange.
The website posted earlier www.red-bag.com <http://www.red-bag.com/> does not give this detail. Please provide me of any links
Thanks & regards,
Danish
âThis message, including any attachments, may contain confidential and privileged information for the sole use of the intended recipient(s). Review, use, distribution or disclosure by others is prohibited. If you receive this message in error, please notify the sender by reply e-mail and delete the message from all computers. Please note that e-mails are susceptible to change. The sender will not accept liability for the improper or incomplete transmission of the information contained in this message.â
[Non-text portions of this message have been removed] Received on Thu May 25 05:20:00 2006
This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:24:10 EDT